NEWS | SOFTWARE | SHEET

How to measure the shuttering area for column

The procedure is easy for computing the shuttering area for every constituents/members of the structure because it is just required to compute the area of the constituent/member over which concrete must be poured.

The formwork or Shuttering refers to the short-term or long-term mold into which concrete or associated substances/materials are poured. Furthermore, the shuttering helps the concrete pouring to get the needed form.

Diverse sort and dimension of shuttering are present in the building construction for different members/constituents with different forms.

The Shuttering area is computed in Square foot or in Square meters on the basis of the sort of unites to be utilized. The shuttering is computed through calculating the surface area that is attached with the concrete surface after the pouring of concrete is completed.

For slab, it is essential to primarily calculate the surface area of the slab and after that the slab perimeter because the shuttering is also going to be used in the slab sides.

To get a clear understanding, check out the subsequent instance for the column and footing shuttering area computation. So as to compute the slab shuttering area, it’s essential to simply compute its perimeter together with the slab surface area in square foot or in square meter.

For Column: Illustration: The column height is three m, the column width is zero point three five m and length is zero point three five m as well as the column footing has a length two point five m, the footing width is two m and the footing thickness is zero point five m.

Calculate the shuttering Area in m2:

Information given:

Footing magnitude
Length equal to 2.5 m
equal to 2 m
Thickness equal to 0.5 m
Column magnitude
Length equal to 0.35 m
Width equal to 0.35 m
Height equal to 3 m

Resolution: Footing Computation: The footing comprises four sides over which shuttering must be utilized. Furthermore, the footing down side is associated with the upper side or ground is open to air so that footing in the spots are neglected for shuttering area computation because no shuttering is required there.

1 Side Area equal to Length x Thickness
equal to 2.5 x 0.5
equal to 1.25 m2
4 Sides Area equal to 4 x 1.25
equal to 5 m2

Column Computation: The shuttering must be offered to the column with four sides. The column bottom side is constantly attached with column footing or upper side of the column is attached with the slab to remove the spots in shuttering region computation.

1 Side Area equal to Width x Height
equal to 0.35 x 3
equal to 1.05 m2.
4 Sides Area equal to 4 x 1.05
equal to 4.2 meter square

Result: Column Shuttering Area equal to 4.2 m2.
Footing Shuttering Area equal to 5 m2.